V-WDM Description and Installation
Procedure
The V-WDM wavelength division
multiplexer combines and separates the 1300nm and 1550nm optical communication
bands. This permits two optical communications to coexist in the fiber
simultaneously. Two fibers are required; each fiber having light traveling in
one direction only. The two different wavelength lasers are combined into a
single transmit fiber for connection to the outside plant and isolated by
wavelength at the far end for the two communication equipment receivers. This
process is duplicated for communication n the reverse direction. Both
optical signals must have the same level before separation, and after
separation must be less than 20dB above the receiver thresholds. Optical
receivers are not wavelength selective which requires the filters in the V-WDM
to provide all the wavelength isolation. The interfering (crosstalk) wavelength
is attenuated a minimum of 30dB below the combined (outside plant) receiving
end fiber level. For optimum operation, the crosstalk, which is similar to
noise, must be both:
a)
well below the
desired wavelength’s receive level (for a low bit error rate)
b)
well below the
receiver’s threshold (so crosstalk will not keep a failed communication link
up)
General Procedure for equipment
1)
Pad (attenuate)
the stronger wavelength before combining in the V-WDM to match the level of the
weaker wavelength at the far end of the outside plant. This pad attenuates only
one wavelength.
2)
Pad each of the
isolated wavelengths coming out of the V-WDM 10 to 20dB above the equipment’s
receiver threshold. This pad attenuates both the wanted wavelength and
the interfering crosstalk wavelength.

Typical Procedure for Nebula
Equipment
It
may be possible to eliminate some or all of the pads depending on the
equipment’s optical parameters and the outside plant fiber loss. A single pad
could be placed on the combined wavelengths provided both receivers have about
the same threshold and both the transmitters have about the same launch and the
plant has about the same loss at each wavelength.

Note:
1)
Use the three
ports described as
2)
Attenuators may
have different values at each wavelength and the value is usually specified at
only one wavelength.
3)
Powering two
V-FAST cards require at least a 12VCD
1.2AMP power supply.
Specifications
0.8 inch wide 3U high passive
optical cards
6 FC connectors total (3 FC
[RX, RX, TX] for transmit; 3 FC [
|
Insertion loss |
Typical 0.7dB |
|
|
Max 3.0dB |
|
Isolation center wavelength |
>30dB |
|
Wavelength range |
1310/1550nm |
|
Optical bandwidth |
+- 20nm |
|
Thermal stability |
<0.3dB |
|
Directivity |
60dB |
|
Polarization dependant loss |
<0.2dB |
The V-WDM can also be
configured to communicate bi-directionally over a SINGLE fiber, one wavelength in each direction. Please
consult the factory.