VE-1S19
VE-1S19 Enclosure (front)
VE-1S19 Enclosure (side)
*Click on images to enlarge
Customer premise enclosure. Intended for installation at the customer site.
The enclosure has a 4" back offset. The unit has two powered card postitions and
one unpowered card position. Configured to hold one or two V-FASTA/B, or
equivalents and V-WDM. Shipped with one position ready for card installation;
two positions covered with a blank plate which can be replaced with another
adaptor plate for card installation. Enclosure fits in a 1U 19" rack or can be
wall mounted with screws .
Part # VE-1S19
VE-3SBP
VE-3SBP FOIRL Shelf for CO (central office)
*Click on images to enlarge
Intended for installation at the CO (central office). Holds 19 V-FASTA/B or
equivalents plus 1 unpowered card. Fits a standard 3U 19" rack (can be manufactured with an offset of
2 inches for fiber bend radius clearance or cabinet door). Shelf with 19 V-FAST
units requires 133 watts (7w x 19 units) or 133w/48v=2.77 Amps (fuse with 5 amp fastblow). There are two -48v power feeds on the back of the shelf. Each feed
powers all card positions and no single point of failure can interrupt shelf
power to any card. Two ground terminals are provided for ease of wiring and are
electrically connected. Heat deflectors must be installed between shelves for
convection cooling or fan trays used if no deflectors are used. Room temperature
at the bottom of a shelf should not exceed 50 degrees C for convection cooling
or 75 degrees C with forced air cooling.
Part# VE-3SBP
Components in rack mount.
*Click on image to enlarge
Pricing
Available upon request
Nebula Products Page